Digital / Microprocessor based pH Meter



Refractometer [Manual, Digital, Automatic]
Magnetic Stirrer with Hot Plate
APPLICATIONS OF HOT AIR OVEN
- Double Walled Oven Universal (Lab. & Memmert Type) is elegantly designed in various applications for microbiology, cell cultivation of animals and plants, food studies; general heating, drying, sterilizing, baking, to perform: material tests, ageing of computer chips, run complex experiments with highly sensitive loads, drying or tempering electronic components, hardening plastic resin. Hot air oven stands for unparalleled precise, even and gentle temperature control.
- Double Walled Oven Universal (Lab. & Memmert Type) is low cost options for heating- for various experiments in, industries, R&D labs, Pharmaceutical, Food & Beverage Industries and Institutions- in the field of Medical, Agricultural and Industrial Research.

SALIENT FEATURES & CONSTRUCTION OF HOT AIR OVEN
- Outer chamber is made of Mild Steel duly powder coated (Standard Model), Inner & Outer S.S. (GMP Model). Inner chamber made of STAINLESS STEEL (304) sheet (Standard Model).
- Inner chamber made of STAINLESS STEEL (304) sheet (Standard Model).
- Forced convection system by Fan &motorized blowers fitted ensures good mixing, strong dispersion and maintains higher temperature uniformity inside the chamber & no cross contamination.
- Thermal loss is prevented by filling mineral wool (Insulation) in space between the outer body & Inner chamber.
- Door Gasket fixed on the double walled door for proper sealing.
- Fitted with heavy hinges with a ball catcher, spring loaded door closing device. Door is duly insulated.
- vapour circulation for over heat release.
- U type air heating elements made of high quality Nichrome/Kanthal wire are placed in ribs, at bottom (Lab. Type) and top with left and right side (Memmert Type) for uniform heat distribution.
- Inner chamber has ribs for placing the shelves at convenient levels. Supplied with 2 or 3 removable shelves.
- Temperature is controlled by electronic digital temperature indicator cum controller from 50°C to 200°C ± 1°C (Lab. Type) &50°C to 250°C ± 1°C (Memmert Type) . fitted on the front panel for easy operations.
- Note:- Laboratory Type in Hot Air Oven heating element fitted only bottom his working Temp. up to 200°C.
- Memmert Type in Hot Air Oven heating element fitted three side his working Temp. up to 250°C.
- Different programme functions can be designed for a wide variety of applications, and even when used
- Temperature is displayed by Digital LED with Set Value and ProcessValue display at front of the oven.
- Front Panel is provided with ON/OFF switch, temperature controller and indicators
- Operating Voltage: 220 Volts AC (50 Hz).
TECHNICAL SPECIFICATIONS OF HOT AIR OVEN
| Inner Chamber in MM (W x H x D) | 355x355x355 | 455x455x455 | 455x455x605 | 605x605x605 | 605x910x605 |
|---|---|---|---|---|---|
| Inches Conversion | 14 x 14 x 14 | 18 x 18 x 18 | 18 x 18 x 24 | 24 x 24 x 24 | 24 x 24 x 36 |
| Capacity (Approx.) | 43 ltrs | 90 ltrs | 105 ltrs | 215 ltrs | 325 ltrs |
| Heating Load | 1.00 KW | 1.50 KW | 1.50 KW | 2. 50 KW | 3.00 KW |
| No. of Shelves | 2 | 2 | 2 | 2 | 3 |
| Temperature Range | 5°C above ambient to 200°C (In Lab. Type) ,Ambient 5°C above ambient to 250°C (In Memmert Type) | ||||
| Temp. Controller | By Microprocessor Based PID Digital Temperature Indicator cum Controller. | ||||
| Temp. Sensitivity | +1°C. | ||||
| Air Circulation | By forced convection system (Optional) | ||||
| Relay | Solid state electronic relay. | ||||
| Auto Tuning System | System is compatible with auto tuning system | ||||
OPTIONAL FEATURES OF HOT AIR OVEN
- Data logger
- Data scanner complete with sensor
- CFR 21 Part 11 compliance software for data logger/scanner
- Safety digital temperature controller
- Timer
NOTE: AIR CIRCULATION FAN OR Motorized Blower IS RECOMMENDED FOR 18”×18”×24” and above Size Model.

Hot Air Oven
Semi Micro Weighing Balance
APPLICATIONS OF WATER BATH
- Double Walled Water Bath generally used for evaporating liquids for boiling the material.
- Double Walled Water Bath is low cost options for heating / boiling ideal tool for Laboratories, Pharmaceutical, Food & Beverage Industries and Institutions.

SALIENT FEATURES & CONSTRUCTION OF WATER BATH
- Double walled made of heavy gauge stainless steel.
- Provided with concentric rings (Removable) of 75mm hole.
- Concentric rings can be removed to accommodate containers of various sizes.
- Heating by immersion heaters.
- Temperature range ambient up to 90oC.
- Temperature is controlled by electronic digital temperature indicator cum controller from 50°C to 90°C ± 1°C
- Operating Voltage: 220 Volts AC (50 Hz)
TECHNICAL SPECIFICATIONS OF WATER BATH
| Internal dimensions (LX W XD) | 250 x 350 x100mm | 300 x 400 x100mm |
|---|---|---|
| No. of Holes | 6 | 12 |
| Holes Dia. | 75 mm | 75 mm |
| Heating Load | 1.0 KW | 2.0 KW |
| Temp. Controller | By Microprocessor Based PID Digital TemperatureIndicator cum Controller. | |
| Temp. Sensitivity | +1°C. | |
| Relay | Solid state electronic relay. | |
| Auto Tuning System | System is compatible with auto tuning system | |
Water Bath
APPLICATIONS OF HEATING PLATE
- Laboratory Heating Plate is a round shape heating plate with diameter 8"
SALIENT FEATURES & CONSTRUCTION OF HEATING PLATE
- Complete body made of P.C.R.C Sheet powder coated OR Complete Stainless Steel Body with top.
- Cast iron top of the plate OR S.S. top is 8" Diameter
- 1500 watts provided with Energy Regulator to control the Temperature up to 300°C.
- Supplied complete with cord & plug to work on Single Phase 220 / 230 volts A.C. supply.

TECHNICAL SPECIFICATIONS OF HEATING PLATE
| Sizes | 8”Dia | 9”Dia | 12”Dia | 10”× 16” | 12”× 18” | 18”× 24” |
|---|---|---|---|---|---|---|
| Shape Type | Round | Round | Round | Rectangular | Rectangular | Rectangular |
OPTIONAL FEATURES OF HEATING PLATE
- Microprocessor based double display PID temperature controller
- Three speed rotary switch for heating

Hot Plate
APPLICATIONS OF BOD INCUBATOR
- Microprocessor controlled, solid-state heating/cooling incubator (BOD Incubator) down to earth.
- BOD Incubator is specially designed for incubation of Biochemical Oxygen demand on water and sewage; can be used as environmental study and growth chamber by incorporating lighting and humidification system.
- BOD Incubator is Used in various applications for microbiology, cell cultivation of animals, plants & food studies- where experiments requiring low temperature conditions. Used for microorganism or activation, good storage and desalting process of enzyme extracts and for preservation of vaccines, insulin, level extracts.

SALIENT FEATURES & CONSTRUCTION OF BOD INCUBATOR
- Robust construction outer chamber is made of Mild Steel duly pretreated& finished with powder coated paint for lasting finish (Standard Model) Inner & Outer S.S. (GMP Model).
- Inner chamber made of STAINLESS STEEL SHEET (304 Grade) (Standard Model).
- Fitted with durable fan OR coaxial blower for forced air circulation at triple walled back to maintain temperature uniformity in the chamber.
- Outer front double walled door is insulated and is fitted with magnetic tape for air tight closing for no temperature loss, provided with lock and key arrangement.
- Door operated illumination lamp is fitted inside the chamber for easy visibility.
- A full view inner plexiglass door enables inspection and monitoring of inner chamber specimens without disturbing the process temperature.
- High grade PUF INSULATION between outer and inner chamber for minimal thermal losses.
- Cooling is done by finned tube evaporator lie in the air circulation path by ISI marked Compressor/Condensing Units CFC free & R-134 aeco friendly refrigerant.
- Heating elements are placed in the path of moving air duly insulated from the body.
- Inner chamber has ribs for placing the shelves at convenient levels. Supplied with 2 or 3 removable shelves.
- Control panel having all controls and circuitry are housed at the top fitted with Temperature controller cum Indicator Microprocessor based with LED display for Set Value (SV) & Process Value (PV) to select any desired temperature on the panel.
- Caster wheel mounted for easy portability.
- BOD Incubator is supplied with cord and plug.
- Operating Voltage: 220 Volts AC (50 Hz).
TECHNICAL SPECIFICATIONS OF BOD INCUBATOR
| Usable Space in CM | 45 x 45 x 45 | 70 x 50 x 50 | 90 x 60 x 60 | 90 x 60 x 60 | 70 x 90 x 60 |
|---|---|---|---|---|---|
| Capacity | 3 cu. ft | 6 cu. ft | 10 cu. ft | 12 cu. ft | 16 cu. ft |
| Approx Volume (Ltr) (Approx.) | 90 ltrs | 175ltrs | 280ltrs | 340ltrs | 440ltrs |
| No. of Shelves | 2 | 2 | 2 | 2 | 2 |
| Temperature Range | 5°C above ambient to 60°C (Resolution0.1°C) | ||||
| Temp. Controller | By Microprocessor Based PID Digital TemperatureIndicator and Controller. | ||||
| Temp. Accuracy | ±0.5°C | ||||
| Display | LED Display for Set Value(SV) and Process Value(PV) | ||||
| Relay | Solid state electronic relay. | ||||
| Auto Tuning System | System is compatible with auto tuning system | ||||
| Air Circulation | By forced convection system | ||||
| Insulation | By High density PUF insulation | ||||
| High Voltage Protection | Through automatic voltage stabilizer (Optional) | ||||
| Electric Supply | 220/230V AC, 50/60Hz | ||||
OPTIONAL FEATURES OF BOD INCUBATOR
- PLC based control system
- Stand by refrigeration system.
- Ethernet / RS485 communication
- Data logger
- Data scanner complete with sensor
- SMS mobile alert system
- Door access security system
- Safety digital temperature controller
- Digital timer
- Safety digital temperature controller
- CFR 21 part 11 compliance software
NOTE: Other Customized Sizes Available on Customer Request.

B.O.D. INCUBATOR
Spectrophotometer


Moisture Analyzer
Binocular Microscope
APPLICATIONS OF VERTICAL AUTOCLAVE
- Autoclave Vertical are most ideal for critical applications requiring assured and reliable total destruction of all living micro- organisms
- Vertical autoclave is low cost options for general sterilization ideal tool for Laboratories, Hospitals, Nursing Homes, R&D labs etc, Pharmaceutical, Food &Beverage Industries and Institutions

SALIENT FEATURES & CONSTRUCTION OF VERTICAL AUTOCLAVE
- Inner & Outer Chamber, constructed from Stainless Steel
- Bucket / Basket Made of Stainless Steel
- Lid made of thick machined stainless Steel Plate
- SS knobs lid ensures user safety & safe locking
- Lid is fitted with pressure gauge, spring loaded safety valve, double safety valve, manual exhaust valve, vacuum breaker as a safety device
- Drain valve facilitates easy cleaning of the chamber
- Moulded joint less silicon rubber gasket
- All internal joints are argon arc welded, ground & polished to give crevice free internals
- Miniature circuit breaker for mains ON/OFF plus safety of control panel Industrial grade energy efficient heaters reduce power bills drastically.
- Audio alarm/ buzzer is raised at the end of the cycle on.
- Voltage: 220 Volts AC (50 Hz)
TECHNICAL SPECIFICATIONS OF VERTICAL AUTOCLAVE
| Inner Dimensions (Dia xHeight) | 250x450mm | 300x500mm | 350x550mm | 400x600mm | 450x600mm | 450x750mm | 550x750mm | 450x900mm |
|---|---|---|---|---|---|---|---|---|
| Inches Conversion | 10 x 18 | 12 x 20 | 14 x 22 | 16 x 24 | 18 x 24 | 18 x 30 | 22 x 30 | 18 x 36 |
| Capacity | 22 ltrs | 40 ltrs | 52ltrs | 80 ltrs | 98 ltrs | 120 ltrs | 152 ltrs | 200 ltrs |
| Working Load | 2.0 KW | 2.0 KW | 3.0 KW | 3.0 KW | 4.0 KW | 4.0 KW | 6.0 KW | 6.0 KW |
| Gasket | Made of Silicon Rubber | |||||||
| Working pressure | 15 PSI | |||||||
| Sterilizing pressure | 1.2 kgf / cm (15psi)at 121°c | |||||||
| Working Temp. | 121 – 125°C | |||||||
| Inner Pressure Tank | Stainless Steel (SS-304) | |||||||
| Basket | Made of Stainless Steel | |||||||
| Lid Opening | Paddle lifting device | |||||||
| Boiler – HydraulicallyTested | Upto +40 psi | |||||||
| Water Draining System | Hand Operated Valve | |||||||
| Heating | BY ISI Marked Immersion Heaters | |||||||
| Steam & Vacuum Release | By Valve | |||||||
| Power Supply | 220/230V AC, 50/60Hz | |||||||
OPTIONAL FEATURES OF VERTICAL AUTOCLAVE
- Digital Double Display PID Temp. Controller Cum Timer
- Electronics Water Level Controller OR Cut Off System For Heater Safety Data logger
- Data scanner complete with sensor
- CFR 21 Part 11 compliance software for data logger/scanner
NOTE: Other Customized Sizes Available on Customer Request.

Vertical Autoclave


Polarimeter [Manual & Digital Automatic]
APPLICATIONS OF BACTERIOLOGICAL INCUBATOR
- Bacteriological Incubator Double walled is elegantly designed in various applications for microbiology, cell cultivation of animals and plants, food studies. Our Incubators stands for unparallel precise, even and gentle temperature control.
- Double Walled Incubators is lowcost options for various experiments in, industries, R&D labs, Pharmaceutical, Food & Beverage Industries and Institutions- in the field of Medical, Agricultural and Industrial Research used for Drying of slides, paraffin embedding, tissue culture work, incubation of antibody test, excellent for Microbiological determinations, crystallization studies and Incubation of hydroxyl steroids.

SALIENT FEATURES & CONSTRUCTION OF BACTERIOLOGICAL INCUBATOR
- Outer chamber is made of Mild Steel duly powder coated (Standard Model) Inner & Outer S.S. (GMP Model).
- Inner chamber made of STAINLESS STEEL (304) sheet (Standard Model).
- Forced convection system ensures good mixing, strong dispersion and maintains higher temperature uniformity inside the chamber.
- Door has double viewing window to observe the sample placed inside the chamber without disturbing the thermal condition.
- Thermal loss is prevented by filling mineral wool (Insulation) in space between the outer body & Inner chamber.
- Door Gasket fixed on the double walled door for proper sealing.
- Fitted with heavy hinges with a ball catcher, spring loaded door closing device. Door is duly insulated.
- Adjustable two ventilation slides control inner air / vapor circulation.
- U type air heating elements made of high quality Ni chrome/Kanthal wire are placed in ribs, at bottom and sides for uniform heat distribution.
- Inner chamber has ribs for placing the shelves at convenient levels.
- Supplied with 2 or 3 removable shelves.
- Temperature is controlled by digital PID controller from 5°C above ambient to70°C ± 1°C. fitted on the front panel for easy operations.
- Proper 37°C ±1°C temperature mention in inner chamber required in air condition room temperature 25°C.
- Different programme functions can be designed for a wide variety of applications, and even when used Temperature is displayed by Digital LED with Set Value and ProcessValue display at front of the incubator.
- Front Panel is provided with ON/OFF switch, temperature controller and indicators.
- Operating Voltage: 220 Volts AC (50 Hz).
TECHNICAL SPECIFICATIONS OF BACTERIOLOGICAL INCUBATOR
| Inner Chamberin MM (W x H x D) | 355x355x355 | 455x455x455 | 455 x 455 x 605 | 605x605x605 | 605x910x605 | |
|---|---|---|---|---|---|---|
| InchesConversion | 14 x 14 x 14 | 18 x 18 x 18 | 18 x 18 x 24 | 24 x 24 x 24 | 24 x 36 x 24 | |
| Capacity | 43 ltrs | 90 ltrs | 120 ltr | 215 ltrs | 325 ltrs | |
| Heating Load | 0.50 KW | 1.00 KW | 1.50 KW | 1. 50 KW | 2.00 KW | |
| No. of Shelves | 2 | 2 | 2 | 2 | 3 | |
| TemperatureRange | 5°C aboveambient to 70°C | |||||
| Temp.Controller | ByMicroprocessor Based PID Digital Temperature Indicator cum Controller. | |||||
| Temp.Sensitivity | ±1°C. | |||||
| Air Circulation | By forcedconvection system | |||||
| Relay | Solid state electronicrelay. | |||||
| Auto TuningSystem | System iscompatible with auto tuning system | |||||
OPTIONAL FEATURES OF BACTERIOLOGICAL INCUBATOR
- CFR 21 part 11 compliance software for data logger
- Data logger
- Data scanner complete with sensor
- Safety digital temperature controller
- Timer
NOTE: AIR CIRCULATION FAN OR Motorized Blower IS RECOMMENDED FOR 18”×18”×24” and above Size Model.
NOTE:
AIR CIRCULATION FAN OR Motorized Blower IS RECOMMENDED FOR 18”×18”×24” and above Size Model.

Laboratory Bacteriological Incubator
APPLICATIONS OF BIOSAFETY CABINET
- BIOSAFETY BIOLOGICAL SAFETY CABINET Class II re-circulates 70% of air through HEPA filter & 30% Exhaust
- Biosafety Cabinet is used to protect personal, product and the environment from exposure to biohazards and cross contamination during routine procedures.
- Used for various applications in the life science, clinical, pharmaceutical and industrial laboratory.
- These Cabinets are designed to provide 3 basic types of protection.
- Personnel protection from harmful agents inside the cabinet.
- Product protection to avoid contamination of the work, experiment or process.
- Environment Protection

SALIENT FEATURES & CONSTRUCTION OF BIOSAFETY CABINET
- Low Cost.
- Low Noise.
- User Friendly Ergonomic Design.
- Controlled Environment Particulate Free Product Protection.
- Aerodynamic designed airflow grille maintains safety by preventing blockage.
- Silent Vibration
- Free Blower ensure noiseless operation.
- The Unit is suitable for CLASS 100 conditions.
- 70% of the air is re-circulated through the HEPA filter.
- The contaminated air is drawn by the blower through the plenum of the cabinet.
- 30% of the air is exhausted from work area.
- Filtered Exhaust - protects ambient environment, and avoids build up, air borne particles.
- The exhaust of Safety Cabinet is connected to the Virus Burn out Unit for product and personnel protection.
- Air is drawn through Pre-Filter and is made to pass through high effective HEPA (High Efficiency Particular Air) filters.
- The efficiency of HEPA Filter is greater than 99.97% down to 0.3 micron.
- Basic material is thick board wood front back top and exterior surfaces are covered with Formica. OR Cold rolled steel duly powder coated OR Stainless Steel (SS-304) (as ordered).
- Working table is made of Stainless Steel Sheet (SS-304 grade).
- Window opens to 20cm±5mm working height with predefined locking device.
- Built in U.V. Germicidal light
- Facilitates sterilization of working area before and after use. Cock - for gas, air or vacuum, (only 1 no.) is provided.
- Working area is illuminated by fluorescent lighting fitted to the unit.
- The blower and motor assembly is statically and dynamically balanced of 1/5 H.P. capacity operates with minimum noise level.
- Supplied complete with cord & plug to work on Single Phase 220 / 230 volts A.C. supply.
TECHNICAL SPECIFICATIONS OF BIOSAFETY CABINET
| Working Table Size | 2′ x 2′ | 3′ x 2′ | 4′ x 2′ | 6′ x 2′ |
|---|---|---|---|---|
| Working Size | 2′ x 2′ x 2′ | 3′ x 2′ x 2′ | 4′ x 2′ x 2′ | 6′ x 2′ x 2′ |
| HEPA Filter Size | 2′ x 2′ x 6″ | 3′ x 2′ x 6″ | 4′ x 2′ x 6″ | 3′ x 2′ x 6″ |
| No. of Motor/Blower | 1 | 1 | 1 | 1 |
| Illumination | 1 x 40 w | 1 x 40 w | 2 x 40 w | 2 x 40 w |
| Cabinet Materiel | Cold Rolled Steel Powder Coated or Stainless Steel (SS-304) | |||
| Work Table | Stainless Steel (SS-304 grade) | |||
| View Window | In work chamber to monitor the samples | |||
| Main Filter | HEPA Filter (99.97% efficient at 0.3micron particles) | |||
| Pre-Filter | High efficiency pre-filter (Washable) | |||
| Sterilization | By U. V. Germicidal Tube in work area | |||
| Manometer | Static pressure analogue type. | |||
| Sliding Sash | Counter balanced door for effortless operation | |||
| Standard Accessory | Gas/Air cock and Multipoint 15/5 Amp. electric socket | |||
| Electric Supply | AC 230V, 50/60Hz | |||
OPTIONAL FEATURES OF BIOSAFETY CABINET
| Static Pressure Manometer | Can be provided at an extra cost |
|---|---|
| Exhaust Ducting | Per running feet cost will be charged extra |
| HEPA Filtration at exhaust | Can be done at an extra cost |
| Virus burn out at Exhaust | Can be done at an extra cost |
| Magnehelic pressure differential gauge | To track filter pressure in lieu of static pressure manometer (Can beprovided at an extra cost) |
| Interlocking of U.V . germicidal tube & fluorescent light | with auto switch off/on mode for motor blower when the door isclosed/open |
| Hour meter totalizer for U.V . light | Can be done at an extra cost |
| Glove Ports and Gauntlets | Can be done at an extra cos |
| Fumigation Tray – for effective disinfection/ decontamination | Can be done at an extra cost |
| Electronic filter choke alarm (Differential pressure monitor). | Can be done at an extra cost |
| Microprocessor LCD controller | With auto switch off mode for motor blower when door is closed. |
| Digital buzzer timer | Sounds an audio alarm on completion of sterilizing time of the chamber |
Bio – Safety Cabinet
APPLICATIONS OF LAMINAR AIR FLOW
- Laminar Air Flow Benches Horizontal are designed so as to meet the requirement of US Federal Standard 209 B (BS 5295) providing particle free air to meet class 100 conditions mainly used for various works that require maintenance of the cleanness and purity.
- It is Ideal for Culture analysis, Bacteriological & Biological applications in Hospitals, Plant Tissue Culture, Labs, Food, Beverage and Electronic industries.
- It provides an economical work environment- suitable for hospitals, drugstore, pharmaceuticals factories, sanitation and anti-epidemic stations.

SALIENT FEATURES & CONSTRUCTION OF LAMINAR AIR FLOW
- Low Cost.
- Low Noise.
- User Friendly Ergonomic Design.
- Controlled Environment Particulate Free Product Protection.
- Basic material is thick board wood front back top and exterior surfaces are covered with Formica. OR Coldrolled steel duly powder coated OR Stainless Steel (SS-304) (as ordered).
- Working table is made of StainlessSteel Sheet (SS-304 grade).
- All interior surfaces are epoxy painted filter seat is carefully formed, installed and checked for leakage.
- Side panels & front doors are made of acrylic transparent plexiglass. The highly efficient HEPA filter maintains the optimum cleanliness and purity.
- The pre-filter fitted extends the life of HEPA filter drastically. Air drawn through pre-filter is made to pass through highly effective HEPA (High Efficiency Particular Air) filters having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all air-borne particles of size 0.3 micron and larger.
- Working area is illuminated by fluorescent lighting fitted to the unit.
- The blower and motor assembly is statically and dynamically balanced of 1/5 H.P. capacity operates with minimum noise level.
- Supplied complete with S.S. Table Top, Transparent front door, Static Pressure Manometer. Built in U.V. Germicidal Light and Cock for gas, air or vacuum line, HEPA filters and pre-filter.
- Supplied complete with cord & plug to work on Single Phase 220 / 230 volts A.C. supply.
TECHNICAL SPECIFICATIONS OF LAMINAR AIR FLOW
| Working Table Size | 2′ x 2′ | 3′ x 2′ | 4′ x 2′ | 6′ x 2′ |
|---|---|---|---|---|
| Working Size | 2′ x 2′ x 2′ | 3′ x 2′ x 2′ | 4′ x 2′ x 2′ | 6′ x 2′ x 2′ |
| HEPA Filter Size | 2′ x 2′ x 6” | 3′ x 2′ x 6 | 4′ x 2′ x 6” | 3′ x 2′ x 6” |
| No. of Motor/Blower | 1 | 1 | 1 | 2 |
| Illumination | 1 x 20 w | 1 x 20 w | 2 x 40 w | 2 x 40 w |
| Main Filter | HEPA Filter (99.97% efficient at 0.3micronparticles) | |||
| Pre-Filter | High efficiency pre-filter (Washable) | |||
| Sterilization | By U.V. Germicidal Tube in work area | |||
| Front Door | Made of Plexi Glass OR Acrylic | |||
| Standard Accessory | Gas/Air cock | |||
| Electric Supply | AC 230V, 50/60Hz | |||
OPTIONAL FEATURES OF LAMINAR AIR FLOW
| Spare HEPA Filters | Can be provided at an extra cost |
|---|---|
| Magnetic Gauge | (To track filter pressure) in lieu of staticpressure manometer. |
| Interlocking | U.V. Germicidal tube & fluorescent light withauto switch off/on mode for motor blower when the door is closed/open. |
| Hour Meter totalizer | For U.V. light |
| Microprocessor LCD Controller with Auto Switchoff mode | For motor blower when door is closed. Digitalbuzzer timer sounds an audio alarm on completion of sterilizing time of thechamber and the switches off U.V. germicidal tube and automatically switchesON the fluorescent light, alerting the user that the bench is ready for use |
| Can be fitted with microchip controlledelectronic digital indicator | To display air flow rate fitted with sensor |
Laminar Air Flow
Gerber Centrifuge